Next, we advised the addition of Renovation plaster to a depth of 5-7 mm, followed by a finishing plaster. Plaster should take place using Wykamol’s Renovation Plaster, ideally 48 hours after the final coat of Tanking Slurry has been applied. Replastering Specifications (e. section, prior to an application of Renovation. re-plaster with no more damp renovation plaster 5. VAT £40. Bargain Prices. incidence of condensation. 00. 3. Allow the SBR Latex bonding compound to become tacky but not dry before applying Renovation Plaster as normal. Paint it on as a key for the renovating plaster coat. Replastering Specifications (e. VAT. CM8 Mesh Membrane is a versatile membrane which incorporates a tough HDPE mesh lathing. Wykamol Group Ltd. sheet for application instructions, which is available upon request orWykamol Renovating Plaster should be used as detailed below and in accordance with the recommendations in BS 5492:1990 Code of Practice for Interior Plastering. 3. Pay in 3 equal installments with 0% interest. P333+P313 - If skin irritation or rash occurs: Get medical advice/attention. Product Description. Application should be carried out within two days of the final coat being applied. This is scratch finished and then allowed to set before applyingProperty preservation. Can Be Used in All Types of Masonry. • Prime the NO MORE DAMP Renovation Plaster or existing gypsum/ lime plaster finish with NO MORE DAMP SBR Latex, mixed 1:1 with water. 00 (inc. The cementitious tanking complies with BS 8102. Plaster should take place using Wykamol’s Renovation Plaster, ideally 48 hours after the final coat of Tanking Slurry has been applied. PLASTER FINISH: Wykamol CM8 Mesh Membrane can be finished in accordance with standard plastering techniques (BS 5492:1990) using proprietary lightweight plaster, such as No More Damp Renovation Plaster. Add to cart. 1% assessed in accordance with. +44 (0) 1282 473 100. Wykamol Ultracure 380ml. Coat 1 should be applied to fill the studs and cover the mesh. (no customer review) Add a review. Wykamol Renovation Plaster can also be used in conjunction with Wykamol’s basement systems such as HydraDry or Tanking Slurry. Delivery. Start here!Plaster Finish: Wykamol CM3 Mesh Membrane can be finished in accordance with standard plastering techniques (BS 5492:1990) using proprietary lightweight plaster, such as No More Damp Renovation Plaster. VAT). As waterproofing of concrete and masonry. Over-mixing is to be avoided, and hand-mixing is preferably conducted in a trough using a hoe or plasterer’s drag. If HydraFlex has been applied as part of a DPC, breathable paint . Coat 1 should be applied to fill the studs and cover the mesh. No More Damp Renovation plaster available from Toner Dampproofing supplies! The One Stop Damp Shop ! render or plaster, wood, dust, grease, oil, organic growth or other foreign materials that may cause contamination or adversely affect adhesion properties. Plaster should take place using Wykamol's Renovation Plaster, ideally 48 hours after the final coat of HydraDry has been applied. apply directly to the cured tanking slurry. Apply in line with relevant data sheet, which is available upon request or can be downloaded from our website. com. The perlite reduces heat loss and condensation. 1% assessed in accordance with REACH Annex XIII Wykamol Renovating Plaster 10. 120 Litres of gauging water in dry sand per 250 Kg of cement. Managing Director at Wykamol group 1mo Report this post Report Report. Liner ISO-THERM 5. Back Submit. 60 inc. Wykamol Group is a leading UK manufacturer of specialist products for construction and renovation. sales@arsstore 08:00 - 17:00; 01329 235252; sales@arsstore. Contractor Training Courses. Easy to use - very light weight and premixed for quality control. Click & Collect. Contents. g. Wykamol Renovation Plaster). Pay in 3 equal installments with 0% interest. a word of caution make sure you are mixing the backing coat in a well vented. 5492:1990) using proprietary lightweight plaster, such as No More Damp Renovation Plaster. 4. Plaster should take place using Wykamol’s Renovation Plaster, ideally 48 hours after the final coat of HydraDry has been applied. A high performance bonded mesh allows multiple finishes to be applied directly to the membrane. NO MORE DAMP RENOVATION PLASTER Safety Data Sheet 05/08/2022 (Issue date) GB - en 2/9 POISON CENTER or doctor. NO MORE DAMP Renovation Plaster is designed to have similar properties to a 1:1:6 cement:lime:sand plastering mortar. Renderproof is an additive designed for use in externalthe Wykamol Technical Department for further advice. Wykamol Renovation Plaster is a salt inhibiting, damp resistant plaster for use after a damp-proof system has been installed. D. Wykamol CM 60mm Plaster Plugs Without Seals – 200 PackPlaster Finish: Wykamol CM3 Mesh Membrane can be finished in accordance with standard plastering techniques (BS 5492:1990) using proprietary lightweight plaster, such as No More Damp Renovation Plaster. Over-mixing is to be avoided, and hand-mixing is preferably conducted in a trough using a hoe or plasterer’s drag. They ensure a water tight application of the Wykamol Cavity Drain Membrane System when used with the tailor made Thermoplastic Elastomer seals. Delivery. Leyburn: 19 in stock. 45 £28. Add to cart Loading. VAT. Renderproof 25 Litre in Pink. Start A Project. Product identifier Product. ex. Coverage. MORE DAMP Renovation Plaster, Salt Neutraliser and Renderproof). 1 litre concentrate should treat 5m² to 10m². Item 1 of 8. The renovation plaster is. Wall 2. Alternatively, any of the sand-cement or sand-lime-cement. stopping mould issues the #wykamol way , easily and increasing the thermal performance of the wall . Explore Home About Wykamol. Ultracure Damp-proofing Cream 380 ml (comes with extendable plastic nozzle) Ultracure Damp-proofing Cream 600 ml. Coat 1 should be applied to fill the studs and cover the mesh. It complies with BS 8102 for Type-A barrier protection. WHEN APPLYING TO PLASTERBOARD • Wykamol recommends an application of NO MORE DAMP SBR Latex, mixed 1:1 with water, to. All Branches In Stock. Alternatively, any of the sand-cement or sand-lime-cement replastering specifications described in Product Sheet 5 are suitable. Coverage: Will vary dependent on the type of substrate and surface. com. It is advisable to leave walls injected with Ultracure© cream to dry for as long as possible, and for at least 14 days, before removing excess salts and commencing re-plastering. Gypsum plasters must not be used in direct contact with NO MORE DAMP Tanking slurry. Rising damp is a common problem, either because no damp proof course (DPC) has been installed, or because a physical membrane has failed or been 'b. Wykamol Renovation Plaster is designed to have similar properties to a 1:1:6 cement:lime: sand plastering. Liner ISO-THERM 5. 30 in stock - Usually Dispatched in 3-5 Working Days. Wykamol Waterproofing. com Wykamol Group Ltd Boran Court Network 65 Business Park,. Wykamol Renovation Plaster is a BBA approved, fibre reinforced, lightweight, cement/lime plaster formulated for a range of applications, including replastering after the successful. Wykamol Renovation Plaster). The perlite reduces heat loss and condensation. SKU: 81106. Back Submit. March 26, 2022. Thistle Dri-Coat Plaster (Cement Based Renovating) 25kg Sign in or Select a branch to see available stock and prices. 3. Perlite lightweight aggregates replace a proportion of the sand. 20kg Wykamol Renovating Plaster - No More Damp. 120 Litres of gauging water in dry sand per 250 Kg of cement. only as good as construction joints! Don't forget waterbars, Plate or injection hoses. Another day another #Isotherm project, Great now to be supplying another 2 large local authorities also, news to. Plastering should take place using Wykamol’s Renovation Plaster within two days of the final coat of mortar being applied. Wykamol Renovation Plaster is a lightweight plaster. 21 inc VAT. 1/4. Wykamol Renovating Plaster should be used as detailed below and in accordance with the recommendations in BS 5492:1990 Code of Practice for Interior Plastering. Wykamol Renovating Plaster is particularly recommended as a means to avoid cold surfaces but a sand:cement plaster incorporating and integral waterproof may also be used . The slimline 3 mm thickness of the membrane allows for an even plaster finish across the wall. Renovation Plaster, ideally 48 hours after the final coat of Tanking Slurry has been applied. Reduces condensation on walls. The products have been specially formulated for effectiveness and ease of use in our laboratories. P333+P313 - If skin irritation or rash occurs: Get medical advice/attention. Resistance to water penetration — when used in conjunction with a Wykamol dpc system, the product resists the. The Wykamol CM8 Mesh Membrane is a high-density polyethylene cavity drain membrane which allows the isolation of wet walls above and below ground. THE WYKAMOL GROUP LTD Unit 3, Boran Court, Network 65 Business Park, Hapton, Burnley, Lancashire BB11 5TH Tel: 0845 400 6666 Fax 0845 400 3333Wykamol Group Ltd Unit 3, Boran Court Network 65 Business Park Hapton, Burnley Lancashire BB11 5TH Tel: 0845 400 6666 Fax: 0845 400 3333. Repeat priming process as detailed in the substrate preparation . Repeat priming process as detailed in the substrate preparation section, prior to an application of Renovation Plaster. This is scratch finished and then allowed to set before applyingthe power of #isotherm#Isotherm doing its thing stopping #Mould and #condensation and what a fantastic install by Stuart Hankinson love seeing these walls being made warmer and…Quantity input for Wykamol Renovation Plaster. apply plaster finish damp-proofing system d 1. Wykamol Renovation Plaster is a lightweight plaster. Click & Collect. Application should be carried out within two days of the final coat being applied. g. Coat 1 should be applied to fill the studs and cover the mesh. 2. the third is suggesting SBR latex bonding and then no more damp wykamol plaster, maybe a slim. Clearance. P312 - Call a POISON CENTRE or doctor if you feel unwell. Over-mixing is to be avoided, and hand-mixing is preferably conducted in a trough using a hoe or plasterer’s drag. The perlite reduces heat loss and. Ultracure Damp-proofing Cream 1 Litre. +44 (0) 845 400 3333. VAT) £30. WYKAMOL NMD HIGH IMPACT PLASTER 20KG. CALL OUR TECHNICAL SUPPORT TEAM ON 0845 400 6666 FOR MORE INFORMATION VISIT TECHNICAL DATASHEET HIGH IMPACT PLASTER FINISH High Impact Plaster Finish is highly durable and designed to provide a quality, long-lasting finish over Wykamol’s Renovation Plaster, or a range ofWykamol’s Renovation Plaster, at least 48-72 hours after the final coat of HydraFlex has been applied. Technical Department for further advice. condensation. The plasterwork should be removed and a damp-proof course (DPC) using Ultracure Damp-proofing Cream should be carried out. Renovating Plaster up to 30 mm) should be applied in one continuous working process. £9. Lightweight, perlite aggregates replace a portion of the sand to reduce heat loss and condensation. +44 (0) 845 400 3333. STORAGE & SHELF LIFERenovation plaster can be used directly on top of Tanking Slurry, but to improve adhesion we recommend first applying SBR Latex as . TECHNICAL DATASHEET. woodeneye Member. Boran Court. Wykamol Renovation Plaster View Product Contact +44 (0) 1282 473 100 +44 (0) 845 400 3333 [email protected] Wykamol Group has been a leader in the field of property renovation and repair for over 80 years. Add to basket. 20kg Wykamol Renovating Plaster - No More Damp. PACK SIZE AND COVERAGE * STORAGE Store between 5°c and 30°c, in cool and frost free conditions. Repeat priming process as detailed in the substrate preparation section, prior to an application of Renovation Plaster. Wykamol Renovation Plaster is a BBA approved, fibre reinforced, lightweight, cement/lime plaster formulated for a range of applications, including replastering after the successful. Description. Wykamol Replastering Specifications are a range of replastering products for use on internal walls, comprising: • Wykamol Renovation Plaster — a pre-mixed, cement-based, lightweight plaster containing perlite aggregate and water-repellent additives; this is the preferred replastering system where there is a likelihood of condensation1:3 cement: sand plaster with Wykamol’s RenderProof incorporated in to protect the Tanking Slurry from impact damage. g. R. VAT. ISSUE 6 - DP12-TDS. Includes 2 Countersunk Screw Holes for Workbench Fixing. Keith Gilby Managing Director. THE WYKAMOL GROUP LTD Unit 3, Boran Court, Network 65 Business Park, Hapton, Burnley, Lancashire BB11 5TH Tel: 0845 400 6666 Fax 0845 400 3333Wykamol CM Plaster Plugs are used for the application of Wykamol Mesh membrane Systems. provide a quality, long-lasting finish over Wykamol’s Renovation Plaster, or a range of other substrates. Spend between £45-£2,000 and checkout with PayPal to apply. As can a 3:1 sand: cement mix. Delivery. Inhibits rusting of angle beads and conduits etc. NOTE: Wykamol’s High Impact Plaster Finish is the only tested finishing plaster which will interact with Wykamol’sRenovation Plaster and Finish Plaster are commonly used after a successful installation of a Chemical Damp Proof Course (DPC) to further prevent issues related to dampness, salt migration, and condensation. ISO. £8. Our Wykamol Product Range include products for use in Basement Waterproofing, Damp Proofing, Gas Proofing, Wood Preservation and Protection, Cellar Conversions and Tanking, and products for Mould and Condensation Control. com Wykamol Group Ltd Boran Court Network 65 Business Park, Burnley, United Kingdom, BB11 5TH. PRODUCT DATA SHEET SILICONATE K Issue 1 (04. Dampstop Mesh Membrane Kit is a 3mm studded damp proofing membrane which is applied, studs facing the wall, using the fixing plugs and tape provided. Renovating plaster for damp proof, tanking and condensation control. 1 The plaster is mixed with clean water (or a gauging solution containing 30 parts of water to one part of Brunolene PS) in clean containers, by hand or mechanically, to a normal plastering consistency. It is advisable to leave walls injected with Ultracure© cream to dry for as long as possible, and for at least 14 days, before removing excess salts and commencing replastering. 00 + VAT Carriage per Bag above any other carriage cost which may also be implemented. 54 (inc. Wykamol Renovating Plaster should be used as detailed below and in accordance with the recommendations in BS 5492:1990 Code of Practice for Interior Plastering. 👍🇬🇧. Application should be carried out within two days of the final coat being applied. 0. In all cases the damp-proof course should, as far as possible, be installed in accordance with British Standard ‘Code of Practice for Installation of Chemical Damp Proof Courses’ BS6576:2005. Apply in line with relevant data sheet, which is available upon request or can be downloaded from our website. If HydraFlex has been applied as part of a DPC, breathable paint must be used on top of any finish. ex. Wykamol Renovation Plaster 10. The fibres control shrinkage and avoid cracking. plastering Specifications (e. (see Wykamol Re-Plastering Specifications and/or contact the Wykamol Technical Department). As waterproofing of concrete and masonry. Add to basket. Leave Wykamol Renovation Plaster to set for a minimum of 48 hours before applying High Impact Plaster Finish. Top with our renovation plaster to protect the tanking. Sovereign Renderlite Finish Plaster is a gypsum based plaster for use as the final coat after Sovereign Renderlite Renovating Plaster. 01282 473 100. Wykamol Launch Unique Anti-Condensation Product ThermalDry - Warmer, Drier, Happier Walls. Home About Wykamol Products. VAT. Expect to use ~ 10 L gauging solution / 50 Kg dry mortar mix. 0845 123 6006National Merchant Manager. Category: Damp Proofing Chemicals. Wykamol Renovation Plaster). Anti-Condensation. Carl Thomas posted images on LinkedInOur range of Wykamol damp proofing products includes the No More Damp Wykamol membrane kit to reduce condensation, as well as the Wykamol Ultracure damp proofing injection cream kit; an effective treatment for brickwork and masonry to control rising damp. Solving issues caused by failed cavity wall. correctly and thoroughly cured. Renovation Plaster can be used in conjunction with basement waterproofing systems such as Tanking Slurry and is part of our Wykamol Eco Product Range due to it’s energy saving properties. It is a BBA Approved product that can be used to replaster walls and ceilings with a smooth or textured finish. TDS Waterproofing. PACK SIZE AND COVERAGE. Quantity input for Wykamol High Impact Finish Plaster. +44 (0) 1282 473 100. CALL THE WYKAMOL TECHNICAL TEAM ON . £23. Apply warm water or proprietary wallpaper stripper with a sponge or. £36. Repeat priming process as detailed in the substrate preparation section, prior to an application of Renovation Plaster. Clearance. 1Render - Plaster Finish 3. P312 - Call a POISON CENTRE or doctor if you feel unwell. Replastering should be carried out in accordance with BS5492:1990 and with the appropriate Wykamol replastering specifications data sheet as soon as. Wykamol Ultracure 600ml. Wykamol Replastering Specifications are a range of replastering products for use on internal walls, comprising: • Wykamol Renovating Plaster — a pre-mixed, cement-based, lightweight plaster containing perlite aggregate and water-repellent additives; this is the preferred replastering system where there is a likelihood of condensationBack Submit. Reduces risk of condensation. Flexible and breathable. Technical Department for further advice. Can Save Considerable Time and Money Re-plastering. In all cases the damp-proof course should as far as possible be. ISSUE 6 - DP12-TDS. Our team are more than experienced in using all. It is safe to use in potable water and can be applied to pond lining. They ensure a water tight application of the Wykamol Cavity Drain Membrane System when used with the tailor made. Internal plaster affected by hydroscopic salts is removed from the area to be treated to a height of 300 mm above the maximum level of the rising damp. Wykamol Membrane Joint Tape 28mm x 2mm x 22. £18. The tailor made Thermoplastic Elastomer seal ensures application of the membrane is water tight. Miss K Giddings. NOTE: Wykamol’s High Impact Plaster Finish is the only tested finishing plaster which will interact with Wykamol’s10. Wykamol Renovation Plaster is used as part of a Damp Proofing System for re-plastering after a Chemical DPC, using products such as DampSolve, DampSolve-40, Ultracure or. Tony Street’s Post Tony Street Managing Director at Wykamol group 1dRead 581 by Huws Gray Ltd on Issuu and browse thousands of other publications on our platform. highly durable and designed to . Provides insulating properties. Wykamol CM Plaster Plugs are fixings to apply mesh cavity drain membranes to the walls of both above and below ground structures. Wykamol Group Ltd Boran Court Network 65 Business Park, Burnley, United Kingdom, BB11 5TH. Alternatively, any of the sand-cement or sand-lime-cement replastering specifications described in Product Sheet 5 of this Certificate are suitable. No More Damp Renovation Plaster View Product Water-proofing & Gas Control Wykamol Fibre Tape View Product None Start A Project Basement Specification Services. In addition to DrySeal, our innovative EcoRange includes ThermalDry Anti-Condensation Coating and Renovation Plaster. g. ack SizeP Product Code Coverage Litre5 SALTNEUT Dependent on level of contamination. 51 each £22. This is scratch finished and then allowed to set before applyingReport this post Report Report. 50. STORAGE & SHELF LIFEReport this post Report Report. VAT. The Wykamol Group has been a leader in the field of property renovation and repair for over 80 years. 7 Once the final coating has hardened fully, a coat of Wykamol Renovating Plaster is applied to protect it from damage in service. The masonry should then be treated with Wykamol Salt Neutraliser followed by a replastering specification with an appropriate salt-resistant product to prevent further damage, such as Wykamol Renovation Plaster or Renderproof. Other hazards Contains no PBT/vPvB substances ≥ 0. Technical Department for further advice. Wykamol CM 60mm Plaster Plugs Without Seals – 200 Pack. Wykamol’s Renovation Plaster, at least 48-72 hours after the final coat of HydraFlex has been applied. Fibres are incorporated into the product to control shrinkage and improve flexural strength. 07. 👍🇬🇧. Tapes & Fixings. quality, long-lasting finish over Wykamol’s Renovation Plaster, or a range of other substrates, including existing gypsum plaster, plasterboard lime based backgrounds & sand cement backgrounds. NO MORE DAMP Renovation Plaster is designed to have similar properties to a 1:1:6 cement:lime:sand plastering mortar. It is advisable to leave walls injected with Ultracure© cream to dry for as long as possible, and for at least 14 days, before removing excess salts and commencing re-plastering. Right back. Wykamol RenderProof Render Additive & Waterproofer. Were ready for new year with our #renovatingplaster and good to catch up finally on production and all ready to go out first week of January . Store off the ground and in dry, frost free conditions. See our Location Locate Find Your Local Expert Our Technical Experts cover all of the UK and are knowledgeable in all aspects of the construction industry, including Damp and Timber, Gas and Waterproofing, and Structural Repairs. 1% assessed in accordance with REACH Annex XIII Yes! Tanking Slurry has been rigorously tested by the British Board of Agrément for the purpose of permanent Do not use Gypsum Plaster in direct contact with Tanking Slurry. Easy to use and works well for making good, I’m using it on an old stone building, it was recommended to me and I would also now recommend to others. Renovation Plaster can be used in conjunction with basement waterproofing systems such as Tanking Slurry and is part of our Wykamol Eco Product Range due to it’s energy saving properties. Fibres are incorporated into the product to control shrinkage and improve flexural strength. Reduces condensation on walls. SKU: 81310. com - 1. A lightweight renovating plaster pre-mix with perlite, fibres & water repellent additives. Premierchoice Ltd. 1 The plaster is mixed with clean water (or a gauging solution containing 30 parts of water to one part of Brunolene PS) in clean containers, by hand or mechanically, to a normal plastering consistency. Wykamol High Impact Plaster Finish is highly durable and designed to provide a quality, long lasting finish over Wykamol’s Renovation Plaster, or a range of other substrates. Qty. Alternatively, any of the sand-cement or sand-lime-cement replastering specifications described. When mixed with clean water and applied correctly, this forms a. +44 (0) 1282 473 100. Leave Wykamol Renovation Plaster to set for a minimum of 48 . plastering Specifications (e. 1% assessed in accordance with. 1/3 As a finish over existing gypsum plaster and lime backgrounds; As part of flood remediation works; Wykamol Renovation Plaster is a BBA approved, fibre reinforced, lightweight, cement/lime plaster formulated for a range of applications, including replastering after the successful installation of a Wykamol chemical damp-proof course (DPC). 5 Metres. Collection Select your store. 14 inc VAT. Classification of the substance or mixture 24 hrs. g. NO MORE DAMP Renovation Plaster is a BBA Approved, fibre reinforced, lightweight, cementitious plaster formulated for replastering after the successful installation of Wykamol’s chemical damp-proof injection systems. +44 (0) 845 400 3333. Renderproof 25 Litre in Pink. VAT. Over-mixing is to be avoided, and hand-mixing is preferably conducted in a trough using a hoe or plasterer’s drag. Includes 2 Countersunk Screw Holes for Workbench Fixing. This is scratch finished and then allowed to set before applyingSimon Smith posted images on LinkedIn. It is particularly useful where improved thermal performance is required, reducing the risk of condensation on external walls. 100 pages of waterproofing and Gas solutions , only 1 week to go for our biggest brochure yet , more choice more problem solving and moreGreat to have our own in house manufacturing facility. Delivery. 1 Walls Slimline Mesh can be finished in accordance with normal plastering techniques (BS 5492:1990) using proprietary lightweight plasters e. 1 The plaster is mixed with clean water (or a gauging solution containing Brunolene PS) in clean containers, by hand or mechanically, to a normal plastering consistency. TECHNICAL DATASHEET. ISO-Therm Adhesive 4. Back Submit. Note: DO NOT apply Thistle Multi-Finish on top of Renovation Plaster. 27 in stock. OVERCOATING & FINISHING HydraDry Universal Mortar is suitable for overcoating, once cured in line with curing and ventilation guidelines. Wykamol Renovation Plaster is a BBA approved, fibre reinforced, lightweight, cement/lime plaster formulated for a range of applications, including replastering after the successful installation of a Wykamol chemical damp-proof course (DPC). STORAGE & SHELF LIFE Renovation plaster can be used directly on top of Tanking Slurry, but to improve adhesion we recommend first applying SBR Latex as . PACK SIZE AND COVERAGE * STORAGE Store between 5°c and 30°c, in cool and frost free conditions. The Wykamol CM8 Mesh Membrane is a high-density polyethylene cavity drain membrane which allows the isolation of wet walls above and below ground. STORAGE & SHELF LIFEFind many great new & used options and get the best deals for 20kg Wykamol Renovating Plaster - No More Damp- Renovation Plaster at the best online prices at eBay! Free delivery for many products!Wykamol Renovation Plaster is a BBA Approved, fibre reinforced, lightweight, cementitious plaster formulated for plastering after the successful installation of Wykamol’s chemical damp-proof injection systems. g. provide a quality, long-lasting finish over Wykamol’s Renovation Plaster, or a range of other substrates. They ensure a water tight application of the Wykamol Cavity Drain Membrane System when used with the. Wykamol NMD High Impact Plaster Finish 25kg. inc. . ISP Great to see more of our products…Wykamol Renovation Plaster. - 25kgLeave Wykamol Renovation Plaster to set for a minimum of 48 hours before applying High Impact Plaster Finish. Internal plaster affected by hydroscopic salts is removed from the area to be treated to a height of 300 mm above the maximum level of the rising damp. Refer to relevant data sheet for application instructions, which is available upon request or can be downloaded from our website. Coat 1 should be applied to fill the studs and cover the mesh. NO MORE DAMP RENOVATION PLASTER Safety Data Sheet 05/08/2022 (Issue date) GB - en 2/9 POISON CENTER or doctor. Our Wykamol Product Range include products for use in Basement Waterproofing, Damp Proofing, Gas Proofing, Wood Preservation and Protection, Cellar Conversions and Tanking, and products for Mould and Condensation Control. Wykamol Renovating Plaster is particularly recommended as a means to avoid cold surfaces but a sand:cement plaster incorporating and integral waterproof may also be used . P333+P313 - If skin irritation or rash occurs: Get medical advice/attention. Diagram Key 1. +44 (0) 1282 473 100. Tony Street’s Post Tony Street Managing Director at Wykamol group 3dplace using Wykamol’s cementitious Renovation Plaster, Universal Mortar or a 1:3 cement: sand plaster with Wykamol’s RenderProof incorporated in to protect Tanking Slurry from impact damage. Retards mould growth. Note: DO NOT apply Thistle Multi-Finish on top of Renovation Plaster. All traces of previous gypsum plaster must be removed. More great drawings being carried out showcasing our Mould and condensation solutions , being able to draw in 3d to show typical repairs and strategies to. Plastering. FOR MORE INFORMATION VISIT. It is advisable to leave walls injected with Ultracure© cream to dry for as long as possible, and for at least 14 days, before removing excess salts and commencing replastering. Sign in or. This will take approx. The method of using backing plaster with a skim coat is today generally only used for property renovation as new build houses typically use plasterboard for dry lining walls. All Branches In Stock. Sign in or. quality, long-lasting finish over Wykamol’s Renovation Plaster, or a range of other substrates, including existing gypsum plaster, plasterboard lime based. Wykamol; Price, £ Clear – Filter. 4. Does the Tanking Slurry have BBA Approval? Yes! The British Board of Agrément certifies Wykamol Tanking Slurry. Wykamol Renovation Plaster is a BBA Approved, fibre reinforced, lightweight, cementitious plaster formulated for replastering after the successful. High Impact Plaster Finish is designed to provide a quality, long-lasting finish as part of the No More Damp Replastering System, after the installation. . A new and innovative patented textile based thermal system . condensation. Thistle universal one coat plaster by British Gypsum is a versatile undercoat and finish plaster that can be used on brick, block, plasterboard, and concrete surfaces. Wykamol No More Damp Renovating Plaster 20Kg. Waterproofing & Damp Proofing. Allow the SBR Latex bonding compound to become tacky but not dry before applying Renovation Plaster as normal. Tony Street’s Post Tony Street Managing Director at Wykamol group 6moWykamol stock a huge range of masonry repair products including the brilliant helical CDT wall tie , easy to install , non expanding forces , only 6mm hole…You can repair walls more quickly with this quick-setting patching plaster so you can move on to the next job sooner.